Turn off the projector, and unplug the AC power cord

from the AC outlet.
Turn over the projector and remove the air filters by

pulling the latches upward.

1

2

Air filters prevent dust from accumulating on the surface of the optical elements inside the projector. Should the

air filters become clogged with dust particles, they will reduce cooling fans’ effectiveness and may result in a

buildup of internal heat and adversely affect the life of the projector. Clean the air filters by following the steps

below.

Clean the air filters with a brush or rinse them softly.

When rinsing the air filters, dry them well.

3

Replace the air filters properly. Make sure that the air

filters are fully inserted.

4

CAUTION

Do not operate the projector with the air filters

removed. Dust may accumulate on the optical

elements degrading picture quality. Do not put

anything into the air intake vents. Otherwise it may

result in malfunction of the projector.

RECOMMENDATION

We recommend avoidin� dusty/smoky environments
when you operate the projector. Usa�e in these
environments may cause poor ima�e quality.

When you use the projector under dusty or smoky

conditions, dust may accumulate on the lens, LCD panels,

or optical elements inside the projector degrading the

quality of a projected image.

When the symptoms above are noticed, contact your

authorized dealer or service station for proper cleaning.

Note:
When reinserting the air filters, be sure that
the slit part is facing the outer side.

Cleanin� the Air Filters

Maintenance and Cleanin�

Be sure to reset the Filter counter after cleaning or replacing the filters.

Press the MENU button to display the On-Screen

Menu. Use the Point

◄►

buttons to move the red

frame pointer to the Setting Menu icon.
Use the Point

▲▼

buttons to move the red frame

pointer to Filter counter and then press the SELECT

button. A dialog box appears showing the total

accumulated time of the filter use, a timer setting

option, and the reset option. Select Reset and the

“Filter counter Reset?” appears. Select [Yes] to

continue.

1

Resettin� the Filter Counter

Filter counter

Another confirmation dialog box appears, select [Yes]

to reset the Filter counter.

Air filters

Pull up and remove.

Select Reset and

the “Filter counter

Reset?” appears.

Select [Yes],

then another

confirmation

box appears.

Select [Yes] again

to reset the Filter

counter.