beautypg.com

Settin – Sanyo PLC-WXE45 User Manual

Page 49

background image

49

This function is used to reset the lamp replacement

counter. When replacing the projection lamp, reset the lamp

replacement counter by using this function. See page 58 for

operation.

Lamp counter

This function provides the following options in the cooling

fans’ operation after turning off the projector (p.19).

L1 …… Normal operation

L2 …… Slower and lower-sound than the normal

operation (L1), but it takes longer to cool down

the projector.

Fan

Settin�

Choose the running speed of cooling fans from the following

options according to the ground elevation under which you

use the projector.

Off ............ Normal speed. Set this function to “Off”

when using the projector in non-high altitude

environment.

On 1 ......... Faster than Off mode. Select this mode when

using the projector in high altitudes (about

1,200 meters or more above the sea level)

where the fans have less cooling effect.

On 2 ......... Faster than On 1 mode. Select this mode

when using the projector in higher altitudes

than above where the fans have lesser cooling

effect.

Fan control

Note:
Fan noise becomes louder in On 1 and On2.
Failure to set the running speed of cooling
fans properly may affect the projector life.

Note:
Setting “Fan control” to On1 or On2 affects L2
operation in “Fan.”

This function is used to set a frequency for the filter

cleaning.

When the projector reached a specified time between

cleanings, a Filter warning icon appears on the screen,

notifying the cleaning is necessary. After cleaning the filter,

be sure to select RESET and set the timer. The Filter

warning icon will not turn off until the filter counter is reset.

For details about resetting the timer, refer to “Resetting the

Filter Counter” on page 55.

Filter counter

Filter warning icon appears on the screen at a set

time.

Fi�.

Filter warning icon

Note:

This icon also appears at turning on.

Note:

• At selecting input source, the icon (Fig.2)
will appear.
• The Filter warning icons (Fig.1 and Fig.2)
will not appear when the Display function
is set to “Off” (p.41), during
“Freeze”(p.23), or "No show" (p.24).

Filter counter

Fi�.1

Filter warning icon

Use the Point

◄►

buttons

to set the timer. Select

from (Off/100H/ 200H/

300H) depending on the

use environment.

This icon appears on the screen when the end of

lamp life is reached.

Note:

This icon also appears at turning on and
selecting input source.

Lamp replacement icon