41

V.34 symbol rate - Symbol rate for V.34 when using
the &T4 and &T5 commands.
0 – 2400

symbols/second

1 – 2743

symbols/second

2 – 2800

symbols/second

3 – 3000

symbols/second

4 – 3200

symbols/second

5 – 3429

symbols/second

A valid combination of symbol rate (S41) and data rate
(&G) must be selected.
Symbol Rate

Allowable Data Rates

2400

2400 – 21600

2743

4800 – 26400

2800

4800 – 26400

3000

4800 – 28800

3200

4800 – 31200

3429

4800 – 33600

0

0–5

42

Blacklisting—The ISOmodem does not dial the same
number more than two times in S44 seconds. An
attempt to dial a third time within S44 seconds results
in a BLACKLISTED result code. If the blacklist mem-
ory is full, any dial to a new number will result in a
BLACKLIST FULL result code. Numbers are added to
the blacklist only if the modem connection fails. The
%B command lists the numbers on the blacklists.
0 – disabled
1 – enabled

0 (disabled)

0–1

43

Dial attempts to blacklist.
When blacklisting is enabled with S42, this value con-
trols the number of dial attempts that result in a num-
ber being blacklisted.

4

0–4

44

Blacklist Timer
Period during which blacklisting is active

180

0–255

seconds

50

Minimum on-hook time—Modem remains on-hook for
S50 seconds. Any attempt to go off-hook is delayed
until this timer expires.

3

0–255

seconds

51

Number to start checking for an outside PBX line.

1

0–9

Table 45. S-Register Descriptions (Continued)

Definition

S Register

(Decimal)

Function

Default

(Decimal)

Range

Units

This manual is related to the following products: