beautypg.com

A n 9 3 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 120

background image

A N 9 3

120

Rev. 1.3

5.7.21. U87 (Synchronous Access Mode Configuration Register)

U87 SAM Synchronous Access Mode Configuration Options

Bit

Name

Function

15:11

Reserved

Read returns zero.

10

MINT

Minimal Transparency
Host software must always set this bit.
0 = Generate two-byte transparency sequences. This option will use codes
through (if possible) for received data containing two back-to-
back bytes requiring transparency (Rev C and later).
1 = Generate one-byte transparency sequences. This option will only use codes
through for received data (Rev B and later).

9

SERM

Special Error Reporting Mode
0 = Ignore unrecognized in-band commands.
1 = Generate <0x45> (“E” for error) in response to any unrecognized in-band
commands.

8

FSMS

Framed Sub-Mode Startup
0 = Upon successful connection, enter Transparent Sub-Mode.
An
is required to enter Framed Sub-Mode.
1 = Upon successful connection, immediately enter Framed Sub-Mode. The first
received (from a successful hunt) is transformed into an .

7:0

XMTT

Transmitter Threshold
This value represents the number of bytes before a transmission is started. The follow-
ing values are special:
0

The same as ten. Upon receipt of ten bytes, data are transferred. The DTE must

supply a closing flag within the required time or an underrun will occur.
255 The same as infinity, e.g. never start a packet until the closing flag is received.