beautypg.com

An93 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 205

background image

AN93

Rev. 1.3

205

AT+VRX

CONNECT

Trigger receive operation. The first byte
after the newline character following the
CONNECT message will be the first data
stream byte.

[Voice Stream]

Receive OGM voice stream. During voice
stream capture, the user can adjust the
UC0 value via the and
commands. The host voice
driver will need track the number of adjust-
ments and update the +VGR value for
future use.

OK

Terminate the receive operation. The
modem will respond with to
mark the end of the data stream. The OK
denotes the return to command mode. A
Handset Lowered Event, timeout, or silence
event can trigger the transmis-
sion.

AT:U0B1,0

OK

Disable Si3000-to-DAA transmit gain path.
This ensures codec tones are not sent to
the FDV and DTMF.

AT:U199|A

OK

Mute the microphone and speaker paths to
the codec.

AT:U72,0108

OK

Configure Si3000 Register 1:
Disable speaker driver
Enable line output driver
Disable telephone instrument driver
Disable MBIAS output

AT:U72,05D7

OK

Configure Si3000 Register 5:
20 dB Line In gain
Enable Line In
20 dB MIC input gain
Mute MIC input
Mute telephone instrument input
Enable IIR filter

AT:U72,065E

OK

Configure Si3000 Register 6:
0 dB RX PGA gain
Enable Line Out
Disable telephone instrument output

AT:U72,075E

OK

Configure Si3000 Register 7:
0 dB RX PGA gain
Enable SPKRL
Mute SPKRR

Table 129. TAM Handset Record OGM (Continued)