beautypg.com

A n 9 3 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 168

background image

A N 9 3

168

Rev. 1.3

19 B2

HDLC Flag detected

Beginning of Packet

92 6E EF 14 65

Spurious data

19 B0

Data byte with more than 6 mark bits in a row. The
modem looks for HDLC flags.

19 B2

HDLC Flag detected

Beginning of Packet

DA BE C6 07 EA D8 31 C2 05 3C FA C8 86 C4

40 E6

Spurious data

19 A0

Transparency code, represents 0x11 data byte found in
receive data.

CA EA A8 F9

Spurious data

19 B2

Calculated CRC not equal FCS. The modem assumes
this is a bad Frame.

Beginning of Packet

8D 00 57 A5 43 29

Spurious data

19 B0

Followed by a data byte with more than 6 mark bits in a
row. The modem looks for HDLC flags.

19 B2

HDLC Flag detected

Beginning of Packet

05 CB 14 9F 7C 2D

Spurious data

19 B0

Followed by a data byte with more than 6 mark bits in a
row. The modem looks for HDLC flags.

19 B2

HDLC Flag Detected

19 B2

If there is 1-bit error received in an HDLC flag, the
modem assumes a new single-byte packet. Since a 1-
byte packet is invalid, 19 B2 is generated by the modem.

19 BA

Loss of Carrier Detected

0D 0A 4E 4F 20 43 41 52 52 49 45 52 0D 0A

NO CARRIER

Table 104. Bit Errors (Continued)

Data

Meaning