AN93

Rev. 1.3

177

+VTS = [,

, ],[...]...

DTMF and Tone Generation
This command can be used to produce single-frequency tones and double-frequency
tones (i.e. DTMF digit). All three parameters are required for correct operation.

Frequency one, which has a range of 0, 200-3200 Hz.

Frequency two, which has a range of 0, 200-3200 Hz.

Duration of the tone(s) in 10 ms units.

For only a single tone, use with zero value for . Bracket syntax can be
used to group sets of tones to generate simple melodies, e.g.
+VTS=[500,0,10],[600,200,20],[700,250,30]

+VTX

Transmit Voice Stream
Enable DTE transmit of voice stream to DCE. The DCE will return a CONNECT
response. The DTE sends the voice stream as defined by the +VSM command. Any
0x10 character in the voice stream must be shielded with a . The DTE issues a
sequence to terminate the transmit stream. The DCE will respond with
followed by OK. The DCE can be configured to terminate the stream
using the DTE/DCE Inactivity Timer, which is configured using the +VIT command.

Table 110. Extended AT+ Command Set (Continued)

Command

Action