+GCI?

List current country code setting (response is: + GCI:)

+GCI = ?

List all possible country code settings.

+IFC Options
+IFC = A
+IFC = A,B

Specifies the flow control to be implemented.
A

Specifies the flow control method used by the host to control

data from the modem

0

None

1

Local XON/OFF flow control. Does not pass XON/XOFF

character to the remote

modem.

2

Hardware flow control (RTS)

B

Specifies the flow control method used by the modem to con-

trol data from the host

0 None
1 Local XON/OFF flow control.
2 Hardware flow control (CTS).

+IPR =

Fixed DTE Rate.

Description

0

Automatically detect the baud rate.

[BPS]

The decimal value of the rate in bits per second.

Note that the parameter represents the DTE rate in bps and
may be set to any of the following values: 300, 600, 1200, 2400,
4800, 7200, 9600, 12000, 14400, 19200, 38400, 57600, 115200,
230400, 245760, and 307200.

+ITF Options
+ITF = A
+ITF = A,B
+ITF = A,B,C

Transmit flow control threshold.
A

Threshold above which the modem will generate a flow off

signal

<0 to 511> bytes

B

Threshold below which the modem will generate a flow on

signal

<0 to 511> bytes

C

Polling interval for indicator
0 to 300 in 10 msec units.

+MR=X

Modulation reporting control.
X Mode
0 Disabled
1 Enabled
If enabled, the intermediate result code is transmitted at the point
during connect negotiation. The format of this result code is as fol-
lows:
+MCR: e.g. +MCR: V32B
+MRR: e.g. +MRR: 14400

Table 39. Basic AT Command Set (Continued)

Command

Action