3 setting the alarmon n software flag, 4 setting the alarmoff n software flag, Setting the – Sun Microsystems Netra 120 User Manual
Page 118: Alarmon, Alarmoff
8-18
Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
8.5.3
Setting the
alarmon
n Software Flag
●
Set the
alarmon
n variable by typing:
where n is the number of the alarm you want to turn on: 1, 2, or 3.
8.5.4
Setting the
alarmoff
n Software Flag
●
To set the
alarmoff
configuration variable, type:
where n is the number of the alarm you want to turn off: 1, 2, or 3.
8.5.5
Stopping the LOM Sending Event Reports to the
Serial A/LOM port
●
Set the
event_reporting
variable on by typing:
Note –
This is the equivalent of using the
lom -E on
command from the Solaris
shell (see Chapter 9).
●
Set the
event_reporting
variable off by typing:
Note –
This is the equivalent of using the
lom -E off
command from the Solaris
shell (see Chapter 9).
lom> set alarmon
n
lom> set alarmoff
n
lom> set eventreporting on
lom> set eventreporting off