beautypg.com

19 at+ceer extended error report, 20 at+cfun set phone functionality, 19 at+ceer – Sony Ericsson GM47 User Manual

Page 114: Extended error report, 20 at+cfun, Set phone functionality, At+cfun=” is interpreted as “at+cfun=0

background image

GM47/GM48 INTEGRATOR’S MANUAL

114

LZT 123 7263 R1C

3.19 AT+CEER

Extended Error Report

Causes the TA to return one or more lines of information text .
Typically, the text will consist of a single line containing the failure
information given by the GSM network in text format.

3.20 AT+CFUN

Set Phone Functionality

Selects the level of functionality in the MS. Level “full
functionality” results in the highest level of power drawn. “Minimum
functionality” results in the minimum power drawn. Manufacturers may
also specify levels of functionality between these two end levels.

Test command returns values supported by the ME as a compound.

Note!

“AT+CFUN=” is interpreted as “AT+CFUN=0”.

Description

Command

Possible Responses

Request an Extended

Error Report

AT+CEER

• +CEER:
• OK

• ERROR

Show if the command

is supported

AT+CEER=?

• OK

• ERROR

Description

characters

The total number of characters, including line terminators,

in the information text shall not exceed 2041 characters.

Text shall not contain the sequence 0 or OK

Description

Command

Possible Responses

Set MS functionality

AT+CFUN=

• +CME ERROR:
• OK

Show the current

setting

AT+CFUN?

• +CFUN:
• +CME ERROR:

Show if the

command is

supported

AT+CFUN=?

• +CFUN: (list of

supported s)

• +CME ERROR:

Description

0

Minimum functionality. Default value

Note: The ME is turned off

1

Full functionality.

Note: If previously turned off, the phone is turned on

This manual is related to the following products: