beautypg.com

Step 3. running system verification, Step 4. additional system verification – IBM RS/6000 44P User Manual

Page 164

background image

a. When the keyboard indicator appears, press F5 on the directly attached

keyboard (5 on the ASCII keyboard) to load the Stand-alone Diagnostics or F6
on the directly attached keyboard (6 on the ASCII terminal keyboard) to load the
Online Diagnostics.

b. Enter any requested passwords.

c. Follow the instructions to select a console.

6. When the Diagnostic Operating Instructions display, go to Step 3. If you are unable

to load the diagnostics, go to “Problem Determination When Unable to Load
Diagnostics” on page 156.

Step 3. Running System Verification

1. On the Diagnostic Operating Instructions screen, press the Enter key.

2. If the terminal type has not been defined, use the Initialize Terminal option on the

Function Selection menu to initialize the operating system environment before you
can continue with the diagnostics.

3. If you want to do a general checkout with minimal operator action, select the

Diagnostic Routines option on the Function Selection menu.

If you want to do a more complete checkout, including the use of wrap plugs, select
the Advanced Diagnostics option on the Function Selection menu. The advanced
diagnostics are primarily for the service representative; they may instruct you to
install wrap plugs to better isolate a problem.

4. Select the System Verification option on the Diagnostic Mode Selection menu.

5. If you want to run a general checkout of all installed resources, Select the All

Resource option on the Diagnostic Selection menu.

If you want to check one particular resource, select that resource on the Diagnostic
Selection menu.

6. Go to Step 4.

Step 4. Additional System Verification

The checkout programs end with either the Testing Complete menu and a message
stating

No trouble was found

or the A Problem Was Detected On (Time Stamp) menu with a SRN (service request
number).

1. Press Enter to return to the Diagnostic Selection menu.

2. If you want to check other resources, select the resource. When you have checked

all of the resources you need to check, go to Step 5.

146

44P Series Model 170 User’s Guide