beautypg.com

Acronyms, Memory exerciser – IBM RS/6000 44P User Manual

Page 155

background image

a

Acknowledge an error

b

Back one page

c

Toggle between cycle count and last error

e

View the AIX error log

f

Page forward one page

q

Return to Main Menu

r

Refresh screen

s

Enable or disable beep on error

x

Exit system exerciser

Acronyms

The following list describes abbreviations used in the exerciser reports. To toggle
between two states for (example, Activate/Halt Devices), use the number of the device.

Acronym

Description

COE

Continue on error (use number to select.

CP

Device has run the specified number of cycles and is not running

DD

Exerciser has been terminated by a signal

ER

Device has stopped with an error

HG

Device is hung

HOE

Halt on error (use number to select)

RN

Device is running

ST

Device is stopped

Memory Exerciser

The memory exercisers are labeled

memx

, where x is a number for the exerciser.

Multiple exercisers can be active.

The memory exerciser requests as many memory buffers as possible from AIX. The
exerciser then fills the memory buffers with specified bit patterns, then reads and
compares the memory buffers to the specified bit patterns.

On systems with multiple processors, a process is started for each processor. The free
memory space is split evenly between the available processors, thus reducing the time
required to exercise all of the memory.

If the system is working properly, no comparison errors are produced. If a
nonrecoverable memory error occurs, the system crashes. Recoverable memory errors
are logged by the AIX operating system.

The following items must be available to run this service aid:

v

Online diagnostics loaded in maintenance mode

v

128 KB of free space in /etc/lpp/diagnostics/data

v

The following commands must be available:
vmstat
lsps
bootinfo

Chapter 6. Introducing Tasks and Service Aids

137