Display Service Hints
This service aid reads and displays the information in the CEREADME file from the
diagnostics media. This file contains information that is not in the publications for this
version of the diagnostics. The file also contains information about using this particular
version of diagnostics.
Display Software Product Data
This task uses SMIT to display information about the installed software and provides
the following functions:
v
List Installed Software
v
List Applied but Not Committed Software Updates
v
Show Software Installation History
v
Show Fix (APAR) Installation Status
v
List Fileset Requisites
v
List Fileset Dependents
v
List Files Included in a Fileset
v
List Fileset containing file
Display System Environmental Sensors
This service aid displays the environmental sensors implemented on a CHRP system.
The information displayed is the sensor name, physical location code, literal value of
the sensor status, and the literal value of the sensor reading.
The sensor status can be any one of the following:
v
Normal – The sensor reading is within the normal operating range.
v
Critical High – The sensor reading indicates a serious problem with the device. Run
diagnostics on sysplanar0 to determine what repair action is needed.
v
Critical Low – The sensor reading indicates a serious problem with the device. Run
diagnostics on sysplanar0 to determine what repair action is needed.
v
Hardware Busy – The system has repeatedly returned a busy indication, and a
reading is not available. Try the service aid again. If the problem continues, run
diagnostics on sysplanar0 in problem determination mode to determine what repair
action is needed.
v
Hardware Error - The sensor could not be read because of a hardware error. Run
diagnostics on sysplanar0 in problem determination mode to determine what repair
action is needed.
v
Warning High – The sensor reading indicates a problem with the device. This could
become a critical problem if action is not taken. Run diagnostics on sysplanar0 to
determine what repair action is needed.
v
Warning Low – The sensor reading indicates a problem with the device. This could
become a critical problem if action is not taken. Run diagnostics on sysplanar0 to
determine what repair action is needed.
128