beautypg.com

IBM B50 User Manual

Page 198

background image

The service aid provides the following functions:

Add or delete a resource to the periodic test list
Modify the time to test a resource
Display the periodic test list
Modify the error notification mailing list
Disable or Enable Automatic Error Log Analysis

PCI RAID Physical Disk Identify

This selection identifies physical disks connected to a PCI SCSI-2 F/W RAID
adapter.

This task may be run directly from the AIX command line. The following usage
statement describes the syntax of the command:

Usage

diag -c -d < pci RAID adapter > -T identify

Process Supplemental Media

Diagnostic Supplemental Media contains all the necessary diagnostic programs and
files required to test a particular resource. The supplemental is normally released
and shipped with the resource as indicated on the diskette label. Diagnostic
Supplemental Media must be used when the device support has not been
incorporated into the latest diagnostic CD-ROM.

This task processes the Diagnostic Supplemental Media. Insert the supplemental
media when prompted, then press Enter. After processing has occurred, go to the
Resource Selection list to find the resource to test.

Notes:

This task is supported in Standalone Diagnostics only.
Process and test one resource at a time.
Do not process multiple supplementals at a time.

Run Diagnostics

The Run Diagnostics task invokes the Resource Selection List menu. When the
commit key is pressed, Diagnostics are run on all selected resources.

9-26

7046 Model B50 User's Guide