Step 14

The diagnostics produced an SRN for this problem.

1. Record the SRN and other displayed numbers.

2. Report the SRN to the service organization.

3. STOP. You have completed these procedures.

Step 15

When you are loading the Standalone Diagnostics, the attributes for the terminal
must be set to match the defaults of the diagnostic programs. The tty terminal must
be attached to port S1 on the server.

Are you going to load Standalone Diagnostics and run them from an ASCII
terminal?

NO

Go to “Step 16.”

YES

Go to “Running the Diagnostics from a TTY Terminal” on page 5-3
and be sure your terminal attributes are set to work with the diagnostic
programs.

Return to “Step 16” when you finish checking the attributes. Record any
settings that are changed.

Diagnostic Response

Action

An SRN is displayed.

Go to “Step 14.”

The system hangs.

Report SRN 109-200.

The Testing Complete menu and the

No

trouble was found

message is displayed,

and you have not tested all of the
resources.

Press Enter and continue with the testing.

The Testing Complete menu and the

No

trouble

was found message displayed and

you have tested all of the resources.

Go to “Step 17.”

Chapter 8. Hardware Problem Determination