Select user-defined or resident character sets, Set inter-character spacing, Select user-defined – IBM TM7 User Manual
Page 153: Set code page
4 Reserved
5 Reserved
6 Reserved
7 Reserved
Default:
n = 02
Remarks:
See “Document Handling” on page 157.
Only one station can be set at a time. If you select more than one station,
the command is ignored.
Select User-Defined or Resident Character Sets
RS-232 Syntax:
ESC % n or X'1B;25;n'
where:
n=00
Select resident character sets
n=01
Select user-defined character sets
Default:
n = 00
Remarks:
See “Character Fonts” on page 93 and “Download User-Defined
Characters” on page 112.
Set Code Page
RS-232 Syntax:
ESC t n or X'1B;74;n'
where:
n=00
Code Page 437 - United States
n=01
Code Page 858 - Multilingual
n=02
Code Page 863 - Canadian-French
n=03
Code Page 860 - Portugal
n=04
Code Page 865 - Norway
n=05
Printer’s Generic Code Page
Default:
n = 01
Remarks:
Changing code pages is valid only for resident single-byte character sets.
Double-byte character sets must be downloaded. If user-defined character
sets are enabled, this command will not do anything.
Set Inter-Character Spacing
RS-232 Syntax:
ESC SP n or X'1B20;n'
updated March 18, 2002
Appendix C. RS-232 Programming Information
129