2 radio test mode, 1 access the test mode, Radio test mode -2 4.2.1 – Motorola SSETM 5000 User Manual
Page 64: Access the test mode -2, Table 4-1, Initial equipment control settings -2, Section 4.2: “radio test, D in
November 11, 2004
6881094C12-A
4-2
Performance Checks: Radio Test Mode
4.2
Radio Test Mode
This section provides instructions for performing tests in display radio test mode.
4.2.1
Access the Test Mode
To enter the display radio test mode:
1. Turn the radio on.
2. Within 10 seconds of turning the radio on, press the one-dot side button five times in
succession.
The radio shows a series of displays that give information regarding various version numbers
and subscriber specific information. The displays are described in
NOTE: When you turn the radio on normally, the radio performs a limited self-test. To allow the radio
to perform a full self-test, press and hold the top side button while turning the radio on. If the
self-test is successful, you hear a chirp. If the self-test is unsuccessful, you hear a single, low-
frequency tone and see an error code on the radio’s display. See
the power-up error codes.
Table 4-1. Initial Equipment Control Settings
System Analyzer
Test Set
Power Supply
Monitor Mode: Standard
Spkr/Load: Speaker
Voltage: 7.5 Vdc
Receiver Checks
RF Control: GEN
Output Level: -47 dBm
Modulation: 1 kHz tone
@3 kHz deviation
Frequency: Set to selected
radio RX frequency
Meter: AC Volts
Transmitter Checks
RF Control: MONITOR
Frequency: Set to selected
radio TX frequency
Meter: RF Display
Modulation Type: FM
Attenuation: 20 dB
PTT: OFF (center)
DC On/Standby: Standby
Meter Out: RX
Volt Range: 7.5 Vdc
Opt Sel: ON
Current: 2.5 Amps