Motorola SSETM 5000 User Manual
Page 61
6881094C12-A
November 11, 2004
Test Equipment and Service Aids: Service Aids
3-5
ChipMaster Nozzles:
6680333E28
PA nozzle
Soldering and unsoldering ICs
3
6680332E83
PLCC-28* nozzle
6680332E93
PLCC-32 nozzle
6680332E82
PLCC-44* nozzle
6680332E94
PLCC-52 nozzle
6680332E95
PLCC-68* nozzle
6680332E96
PLCC-84 nozzle
6680332E89
QFP-80 nozzle
6680332E90
QFP-100* nozzle
6680332E91
QFP-132* nozzle
6680334E67
QFP-160 nozzle
6680332E86
SOIC-14/SOL-16J
nozzle
6680333E46
SOL-18 nozzle
6680332E84
SOIC-20 nozzle
6680332E87
SOL-20J nozzle
6680333E45
SOL-24 nozzle
6680332E88
SOL-28J nozzle
6680333E54
TSOP-32 nozzle
6680333E55
TSOP-64 nozzle
* Included with ChipMaster packages
To maintain the integrity of the RF PA, never heat it above 210
°
C while performing repair or
rework procedures. To prevent overheating the RF PA during rework, use a ChipMaster (R1319
or R1321) top-side pre-heat set point of 215
°
C and a Dragon (R1427) bottom-side pre-heat set
point of 204
°
C for 1 minute before and throughout top-side heat application, assuming that the
RF PA is removed from the applied heat 10 seconds after reflow occurs. (The RF PA
temperature does not reach the ChipMaster’s internal set point temperature). All other parts on
the transceiver board can be reworked with ChipMaster top-side heat alone.