Power-up failure—page 2 – Motorola SSETM 5000 User Manual
Page 108
![background image](/manuals/125574/108/background.png)
November 11, 2004
6881094C12-A
9-4
Troubleshooting Charts: Power-Up Failure
Power-Up Failure—Page 2
Investigate
Clock Buffer
Components and
Isolate Problem
This signal may
contain harmonics
and, therefore, may
not appear as a
perfect sinewave.
Signal may
appear for a very
short period of
time (50ms). Use
an oscilloscope
with trigger to
capture signal.
Refer Board to
Service Depot for
Reflash, Patriot,
SRAM, and
FLASH Analysis
Investigate
16.8 MHz
Reference
Oscillator
Probe
16.8 MHz
Signal at R615
Signal
greater than
600mV?
Signal
greater than
600mV?
Check
16.8 MHz
Signal at
C607
Replace
U301
Replace
Problem
Component
Components
OK?
Fixed?
End
Fixed?
Replace
Y301
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
1
2
Note: All components noted on this
chart are VOCON components.