80
8. Printing Procedures (Special prints)
3
Set the “PAGE INC” to “ON”.
Set the “PAGE INC : ON/OFF” to “ON” in “6. SYSTEM” from the MAIN MENU.
4
Set the “MEM&PRINT” to “ON”.
Set the “MEM&PRINT : OFF/ON” to “ON” in “2. KEY SETTING” from the MEMORY SW MENU.
Displaying the source image (image from the input signal)
1
Press the SET
SET
button.
,
“CHANGE : OK/CANCEL” is selected.
,
When changing the setting, select “CANCEL”
2
Press the SET
SET
button.
,
The MAIN MENU is displayed.
3
Press the SET
SET
button.
,
“SAVE PRG 1/2/3” is selected.
,
This menu is used to store the setting in any one of 3 programs (1, 2 or 3).
4
Press the RIGHT
or LEFT
button to select the program number 1, 2 or 3 to store the setting.
,
The setting will be overlaid. In case of keeping the stored program, do not select the program No. in which the setting is
stored.
5
Press the SET
SET
button.
,
The source image (image from the input signal) is displayed.
Pressing the MEMORY button
Note :
1
Display the desired image for the automatic interval printing on the monitor.
2
Press the MEMORY button.
,
The set automatic interval printing starts.
1
Interrupting automatic interval prints
,
When the STOP button on the remote control is pressed, the automatic interval print is interrupted.
,
“MEM&STOP” and “MEM&PRINT” function after the last image of the multi-image is stored in memory.
,