7. Setting the functions (Memory SW menu)

MARGIN CUT

Function

Cut the print paper so that the upper margin is small.

ON .......... Small margin

OFF ........ Behind the margin

This function is convenient when putting the print on prints on records or non-PVC sleeves for print

orchiving. This feature also saves paper.

V POSITION

Function

Adjusting the vertical position of printing image.

Setting area - 40 to +40 ( Change each 2 lines)

When 2-image printing (selected “2” in “IMAGES”) on L size print paper, the printed image will not be

correct depending on memory size. It may be necessary to adjust part of the image in the UP, DOWN,

RIGHT or LEFT direction.

V POSITION function is to adjust the position for UP and DOWN direction of the image in memory and to

print the image in the normal cutting position. This function is available only when printing 2multi-image

on L size paper and selecting “2” in “IMAGES”.

ECHO GAMMA ADJ

Function

Change the gamma value of “ECHO” for medical equipment.

The gamma curve is set for medical equipment in MAIN MENU

4.PRINT GRAD : ECHO . When the

set gamma curve cannot be applied, this function is able to set according to connecting device. The set

value is applied to the value of ECHO.

The gamma characteristic of printed image can be changed by inputting the value of a, b and c on the

gamma curve.

a (cordinates of the x1 point, changed value y1)...... dark part of the image gets

y1

+ : brighter –: darker

b (cordinates of the x2 point, changed value y2 )...... the whole image get

y2

+ : brighter –: darker

c (cordinates of the x3 point, changed value y3 )...bright part of the image gets

y3

+ : brighter –: darker

• At X, input the location of a point on the curve to be moved to Y direction.

• At Y, input the amount of move.

• All the gamma characteristic changes by moving the “y” on a, b or c point.

• The setting area of the points (a, b and c ) is limited.

Select the item to be changed by LEFT or RIGHT shift button.

a: ( , )

← →

b : ( , )

← →

c : ( , )

Change the value by UP or DOWN shift button.

e.g.

1

b (x 2 value, y 2 changing value )..... Change the y value of all of the image.

2

Change the value of a and c.

a : x1=64 y1=0 b : x2=128 y2=0 c : x3=192 y3=0 is the initial setting of “GRAD:ECHO”.

X

Y

a:( x1,y1 )

b:( x2,y2 )

x: cordinates of the x1value, y: changed value y1

c:( x3,y3 )

x1 cordinate
range

x2cordinate
range

x3cordinate
range

y1

y2

y3

a ( cordinates of the x1value, changed value y1)

darker

lighter

Margin cut

ON

OFF