Rs-232c data signal – MITSUBISHI ELECTRIC CP700E User Manual
Page 22
21
4. Connection with external equipment (RS-232C Interface)
4
Press the SET
SET
button.
,
“
CHANGE : OK
” is selected.
5
Select “OK”, then, press the SET
SET
button.
,
The source image (input signal from the equipment connected) is displayed.
0
The setting of COMMAND TYPE is completed.
RS-232C DATA SIGNAL
RS-232C input connector port signal allocation
Pin No.
Signal line name
Description
Directions (From VCP side)
1
F G
Protective
-
-
-
2
T X D
Transmitted data
Output
3
R X D
Received data
Input
4
R T S
Request to send
Output
5
C T S
Clear to send
Input
6
D S R
Data set ready
Input
7
G N D
Signal ground
-
-
-
20
D T R
Data terminal ready
Output
Setting the communication format of the computer
,
Set the communication format as follows:
(1)
Synchronizing system
Asynchronous communication
(2)
Data bit length
8 bits
(3)
Parity bit
Nothing
(4)
STOP bit length
1
(5)
Transmission order
Sent from LSB
(6)
Baud rate (Bit / Sec)
1200, 2400, 4800, 9600
RS-232C function
,
This unit can be controlled through RS-232C terminal.
( The input of image data is not possible.)
Consult with the sales dealer for the details of controlling
method (protocol).
Pin connection
,
Connect the unit with the host computer
through cross-over cable.
Cross-over cable