beautypg.com

Standard specifications, Rating – MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual

Page 6

background image

7

Rating

200V class

400V class

Type FR-F720-

K

0.75 1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

Applied motor capacity (kW)

*1

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

Out

p

ut

Rated capacity (kVA)

*2

1.6

2.7

3.7

5.8

8.8

11.8 17.1 22.1

27

32

43

53

65

81

110

132

165

Rated current (A)

*3

4.2

(3.6)

7.0

(6.0)

9.6

(8.2)

15.2

(13)

23

(20)

31

(26)

45

(38)

58

(49)

70

(60)

85

(72)

114

(97)

140

(119)

170

(145)

212

(180)

288

(244)

346

(294)

432

(367)

Overload current rating

*4

120% 60s, 150% 3s (inverse time characteristics)

Voltage

*5

Three-phase 200 to 240V

Po

wer s

uppl

y Rated input AC voltage/frequency

Three-phase 200 to 220V 50Hz, 200 to 240V 60Hz

Permissible AC voltage fluctuation

170 to 242V 50Hz, 170 to 264V 60Hz

Permissible frequency fluctuation

±5%

Power supply system capacity (kVA)

*6

2.5

4.5

5.5

9

12

17

20

28

34

41

52

65

79

99

110

132

165

Protective structure (JEM 1030)

*8

Enclosed type (IP20)*7

Open type (IP00)

Cooling system

Self-cooling

Forced air cooling

Approx. mass (kg)

1.8

2.2

3.5

3.5

3.5

6.5

6.5

7.5

13

13

14

23

35

35

67

70

70

Type FR-F740-

K

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Applied motor capacity (kW)

*1

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Out

p

ut

Rated capacity (kVA)

*2

1.6

2.7

3.7

5.8

8.8

12.2

17.5

22.1

26.7

32.8

43.4

53.3

64.8

80.8

Rated current (A)

*3

2.1

(1.8)

3.5

(3.0)

4.8

(4.1)

7.6

(6.4)

11.5

(9.8)

16

(13)

23

(19)

29

(24)

35

(30)

43

(36)

57

(48)

70

(60)

85

(72)

106

(90)

Overload current rating

*4

120% 60s, 150% 3s (inverse time characteristics)

Voltage

*5

Three-phase 380 to 480V

Po

wer s

upply

Rated input AC voltage/frequency

Three-phase 380 to 480V 50Hz/60Hz

Permissible AC voltage fluctuation

323 to 528V 50Hz/60Hz

Permissible frequency fluctuation

±5%

Power supply system capacity (kVA)

*6

2.5

4.5

5.5

9

12

17

20

28

34

41

52

66

80

100

Protective structure (JEM 1030)

*8

Enclosed type (IP20)

*7

Open type (IP00)

Cooling system

Self-cooling

Forced air cooling

Approx. mass (kg)

3.5

3.5

3.5

3.5

3.5

6.5

6.5

7.5

7.5

13

13

23

35

35

Type FR-F740-

K

75

90

110

132

160

185

220

250

280

315

355

400

450

500

560

Applied motor capacity (kW)

*1

75

90

110

132

160

185

220

250

280

315

355

400

450

500

560

Out

put

Rated capacity (kVA)

*2

110

137

165

198

247

275

329

366

416

464

520

586

659

733

833

Rated current (A)

*3

144

(122)

180

(153)

216

(183)

260

(221)

325

(276)

361

(306)

432

(367)

481

(408)

547

(464)

610

(518)

683

(580)

770

(654)

866

(736)

962

(817)

1094

(929)

Overload current rating

*4

120% 60s, 150% 3s (inverse time characteristics)

Voltage

*5

Three-phase 380 to 480V

Powe

r s

upply

Rated input AC voltage/frequency

Three-phase 380 to 480V 50Hz/60Hz

Permissible AC voltage fluctuation

323 to 528V 50Hz/60Hz

Permissible frequency fluctuation

±5%

Power supply system capacity (kVA)

*6

110

137

165

198

247

275

329

366

416

464

520

586

659

733

833

Protective structure (JEM 1030)

*8

Open type (IP00)

Cooling system

Forced air cooling

Approx. mass (kg)

37

50

57

72

72

110

110

220

220

220

260

260

370

370

370

*1. The applied motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2. The rated output capacity indicated assumes that the output voltage is 220V for 200V class and 440V for 400V class.
*3. When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter output

current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.

*4. The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty,

allow time for the inverter and motor to return to or below the temperatures under 100% load.

*5. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.

However, the pulse voltage value of the inverter output side voltage remains unchanged at about

that of the power supply.

*6. The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*7. When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type (IP00).
*8. FR-DU07 : IP40 (Except for the PU connector).

2

Standard Specifications