Standard specifications, Rating – MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual
Page 6
7
Rating
200V class
400V class
Type FR-F720-
K
0.75 1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Applied motor capacity (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Out
p
ut
Rated capacity (kVA)
1.6
2.7
3.7
5.8
8.8
11.8 17.1 22.1
27
32
43
53
65
81
110
132
165
Rated current (A)
4.2
(3.6)
7.0
(6.0)
9.6
(8.2)
15.2
(13)
23
(20)
31
(26)
45
(38)
58
(49)
70
(60)
85
(72)
114
(97)
140
(119)
170
(145)
212
(180)
288
(244)
346
(294)
432
(367)
Overload current rating
120% 60s, 150% 3s (inverse time characteristics)
Voltage
Three-phase 200 to 240V
Po
wer s
uppl
y Rated input AC voltage/frequency
Three-phase 200 to 220V 50Hz, 200 to 240V 60Hz
Permissible AC voltage fluctuation
170 to 242V 50Hz, 170 to 264V 60Hz
Permissible frequency fluctuation
±5%
Power supply system capacity (kVA)
2.5
4.5
5.5
9
12
17
20
28
34
41
52
65
79
99
110
132
165
Protective structure (JEM 1030)
Enclosed type (IP20)*7
Open type (IP00)
Cooling system
Self-cooling
Forced air cooling
Approx. mass (kg)
1.8
2.2
3.5
3.5
3.5
6.5
6.5
7.5
13
13
14
23
35
35
67
70
70
Type FR-F740-
K
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Applied motor capacity (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Out
p
ut
Rated capacity (kVA)
1.6
2.7
3.7
5.8
8.8
12.2
17.5
22.1
26.7
32.8
43.4
53.3
64.8
80.8
Rated current (A)
2.1
(1.8)
3.5
(3.0)
4.8
(4.1)
7.6
(6.4)
11.5
(9.8)
16
(13)
23
(19)
29
(24)
35
(30)
43
(36)
57
(48)
70
(60)
85
(72)
106
(90)
Overload current rating
120% 60s, 150% 3s (inverse time characteristics)
Voltage
Three-phase 380 to 480V
Po
wer s
upply
Rated input AC voltage/frequency
Three-phase 380 to 480V 50Hz/60Hz
Permissible AC voltage fluctuation
323 to 528V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Power supply system capacity (kVA)
2.5
4.5
5.5
9
12
17
20
28
34
41
52
66
80
100
Protective structure (JEM 1030)
Enclosed type (IP20)
Open type (IP00)
Cooling system
Self-cooling
Forced air cooling
Approx. mass (kg)
3.5
3.5
3.5
3.5
3.5
6.5
6.5
7.5
7.5
13
13
23
35
35
Type FR-F740-
K
75
90
110
132
160
185
220
250
280
315
355
400
450
500
560
Applied motor capacity (kW)
75
90
110
132
160
185
220
250
280
315
355
400
450
500
560
Out
put
Rated capacity (kVA)
110
137
165
198
247
275
329
366
416
464
520
586
659
733
833
Rated current (A)
144
(122)
180
(153)
216
(183)
260
(221)
325
(276)
361
(306)
432
(367)
481
(408)
547
(464)
610
(518)
683
(580)
770
(654)
866
(736)
962
(817)
1094
(929)
Overload current rating
120% 60s, 150% 3s (inverse time characteristics)
Voltage
Three-phase 380 to 480V
Powe
r s
upply
Rated input AC voltage/frequency
Three-phase 380 to 480V 50Hz/60Hz
Permissible AC voltage fluctuation
323 to 528V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Power supply system capacity (kVA)
110
137
165
198
247
275
329
366
416
464
520
586
659
733
833
Protective structure (JEM 1030)
Open type (IP00)
Cooling system
Forced air cooling
Approx. mass (kg)
37
50
57
72
72
110
110
220
220
220
260
260
370
370
370
*1. The applied motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2. The rated output capacity indicated assumes that the output voltage is 220V for 200V class and 440V for 400V class.
*3. When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter output
current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.
*4. The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty,
allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5. The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the pulse voltage value of the inverter output side voltage remains unchanged at about
that of the power supply.
*6. The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*7. When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type (IP00).
*8. FR-DU07 : IP40 (Except for the PU connector).
2
Standard Specifications