indicates simple mode parameters and

indicates extended parameters. When setting parameters, refer to the instruction manual (applied) and understand instructions.

Pr.

Pr.

Use the high power factor converter (FR-HC) to reduce
harmonics, improve the power factor, or continuously use the
regenerative mode.
For the 75K or more, use the brake unit MT-BU5 or BR5 when the
regenerative brake duty is need to be increased due to frequent
starts and stops. Use the high power factor converter MT-HC to
reduce harmonics, improve the power factor, or continuously use
the regenerative mode.

<55K or less>

<75K or more>

* Pr.70 Special regenerative brake duty

can be set for the 75K or more inverter.

When it is desired to
avoid resonance
attributable to the
natural frequency of a
mechanical system,
these parameters allow
resonant frequencies to
be jumped.

Up to three areas may be set, with the jump frequencies set to
either the top or bottom point of each area.
The value set to 1A, 2A or 3A is a jump point and operation in the
jump zone is performed at these frequencies.
Frequency jump is not performed if the initial value is set to "9999".
During acceleration/deceleration, the running frequency within the
set area is valid.

You can change the PU (FR-DU07) monitor display or frequency
setting to motor speed or machine speed.

When the running speed monitor is selected, each monitor and
setting are determined according to the combination of Pr. 37 and
Pr. 144. (The units within the thick frame are the initial values.)

*1 Motor speed r/min conversion formula

....... Frequency

× 120/number of motor poles (Pr. 144)

Machine speed conversion formula
...... Pr. 37

× frequency/60Hz

For Pr. 144 in the above formula, the value is “Pr. 144-100” when “102 to
110” is set in Pr. 144 and the value is “4” when Pr. 37=0 and Pr.144=0.

*2 The increments for Hz are 0.01Hz, machine speed are 1m/min and r/min

are 1r/min

.

The inverter output frequency is detected and output at the
output signals.

If the set frequency is considered as 100%, output frequency can
be adjusted between

±1% and ±100% with Pr. 41.

This parameter can be used to ensure that the running frequency
has been reached to provide the operation start signal etc. for
related equipment.

When the output frequency reaches or exceeds the setting of Pr.
42
, the output frequency detection signal (FU) is output.
This function can be used for electromagnetic brake operation,
open signal, etc.
When the detection frequency is set in Pr. 43, frequency detection
for reverse rotation use only can also be set. This function is
effective for switching the timing of electromagnetic brake
operation between forward rotation (rise) and reverse rotation
(fall) during vertical lift operation, etc.
When outputting a frequency detection signal besides the FU
signal, set the detection frequency to Pr. 50 . The FU2 signal is
output when the output frequency reaches or exceeds the Pr. 50
setting.

Selection of
regeneration unit

Pr.30 Regenerative function selection

Pr.70 Special regenerative brake duty *

Pr.30 Setting

Regeneration Unit

0 (initial value)

Brake unit (FR-BU, BU)

2

High power factor converter (FR-HC),
power regeneration common converter (FR-CV)

Pr.30 Setting Pr.70 Setting *

Regeneration Unit

0 (initial value)

Not used

1

0%

Power regeneration converter (MT-RC)

10%

Brake unit (MT-BU5)

2

High power factor converter (MT-HC)

Avoid mechanical resonance
points (frequency jump)

Pr.31 Frequency jump 1A

Pr.32 Frequency jump 1B

Pr.33 Frequency jump 2A

Pr.34 Frequency jump 2B

Pr.35 Frequency jump 3A

Pr.36 Frequency jump 3B

Speed display and speed
setting

Pr.37 Speed display

Pr.144 Speed setting switchover

Pr. 37

Setting

Pr. 144

Setting

Output

Frequency

Monitor

Set

Frequency

Monitor

Running

Speed

Monitor

Frequency

Setting

Parameter

Setting

0

0

Hz

Hz

r/min

*1

Hz

2 to 10

Hz

Hz

r/min

*1

Hz

102 to

110

r/min

*1

r/min

*1

r/min

*1

r/min

*1

1 to

9998

0

Hz

Hz

Machine
speed

*1

Hz

2 to 10

Machine
speed

*1

Machine
speed

*1

Machine
speed

*1

Machine
speed

*1

102 to

110

Hz

Hz

r/min

*1

Hz

Pr.

30, 70

Pr.

31 to 36

Pr. 31

Frequency jump

Pr. 32

Pr. 33

Pr. 34

Pr. 35

Pr. 36

Set frequency (Hz)

Pr.

37, 144

Detection of output frequency (SU,
FU, FU2 signal)

Pr.41 Up-to-frequency sensitivity

Pr.42 Output frequency detection

Pr.43 Output frequency detection for reverse rotation
Pr.50 Second output frequency detection

44, 45

Refer to the section about Pr.7, Pr.8

46

Refer to the section about Pr. 0.

47

Refer to the section about Pr. 3.

48, 49

Refer to the section about Pr. 22 and other
relevant parameters.

50

Refer to the section about Pr. 41 and other
relevant parameters.

51

Refer to the section about Pr. 9.

Pr.

41 to 43, 50

Output frequency

(Hz)

ON

Running frequency

Adjustment
range Pr.41

SU

Time

OFF

OFF

Output

frequency

Forward

rotation

Reverse

rotation

Time

Output frequency

(Hz)

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

FU

FU2

Pr.50

Pr.43

Pr.50

Pr.42

Pr.

Pr.

Pr.

Pr.

Pr.

Pr.