MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual
Page 25
Features
Standard
Specifications
Outline
Dimension
Drawings
Operation
Panel
Protective
Functions
Options
Instructions
Motor
Compatibility
W
arranty
Inquiry
Peripheral Devices
Why energy
savings?
Te
rminal Connection
Diagram
Te
rminal Specification
Explanation
Parameter
List
Explanations
of
Parameters
26
Po
w
er
fa
ilur
e
st
o
p
261
Power failure stop selection
0, 1, 2
1
0
262
Subtracted frequency at deceleration
start
0 to 20Hz
0.01Hz
3Hz
263
Subtraction starting frequency
0 to 120Hz, 9999
0.01Hz
60Hz
264
Power-failure deceleration time 1
0 to 3600/ 360s
0.1/0.01s
5s
265
Power-failure deceleration time 2
0 to 3600/ 360s, 9999
0.1/0.01s
9999
266
Power failure deceleration time
switchover frequency
0 to 400Hz
0.01Hz
60Hz
267
Terminal 4 input selection
0, 1, 2
1
0
268
Monitor decimal digits selection
0, 1, 9999
1
9999
269
Parameter for manufacturer setting. Do not set.
299
Rotation direction detection selection at
restarting
0, 1, 9999
1
9999
RS
-4
8
5 c
o
mmu
ni
ca
tio
n
331
RS-485 communication station
0 to 31(0 to 247)
1
0
332
RS-485 communication speed
3, 6, 12, 24, 48, 96, 192,
384
1
96
333
RS-485 communication stop bit length
0, 1, 10, 11
1
1
334
RS-485 communication parity check
selection
0, 1, 2
1
2
335
RS-485 communication number of
retries
0 to 10, 9999
1
1
336
RS-485 communication check time
interval
0, 0.1 to 999.8s, 9999
0.1s
0s
337
RS-485 communication waiting time
setting
0 to 150ms, 9999
1
9999
338
Communication operation command
source
0, 1
1
0
339
Communication speed command source
0, 1, 2
1
0
340
Communication startup mode selection
0, 1, 2, 10, 12
1
0
341
RS-485 communication CR/LF selection
0, 1, 2
1
1
342
Communication EEPROM write selection 0, 1
1
0
343
Communication error count
1
0
R
em
ot
e ou
tput
495
Remote output selection
0, 1
1
0
496
Remote output data 1
0 to 4095
1
0
497
Remote output data 2
0 to 4095
1
0
M
ai
nt
en
anc
e
503
Maintenance timer
0 (1 to 9998)
1
0
504
Maintenance timer alarm output set time
0 to 9998, 9999
1
9999
C
om
m
u
ni
cat
ion
549
Protocol selection
0, 1
1
0
550
NET mode operation command source
selection
0, 1, 9999
1
9999
551
PU mode operation command source
selection
1, 2
1
2
Cu
rr
e
nt
av
er
a
ge
m
oni
to
r
555
Current average time
0.1 to 1.0s
0.1s
1s
556
Data output mask time
0.0 to 20.0s
0.1s
0s
557
Current average value monitor signal
output reference current
0 to 500/0 to 3600A
0.01/0.1A
Rated inverter
current
563
Energization time carrying-over times
0 to 65535
1
0
564
Operating time carrying-over times
0 to 65535
1
0
571
Holding time at a start
0.0 to 10.0s, 9999
0.1s
9999
PID
co
nt
ro
l
575
Output interruption detection time
0 to 3600s, 9999
0.1s
1s
576
Output interruption detection level
0 to 400Hz
0.01Hz
0Hz
577
Output interruption release level
900 to 1100%
0.1%
1000%
611
Acceleration time at a restart
0 to 3600s, 9999
0.1s
5/15s
*1
Differ according to capacities. (55K or less/75K or more)
Function
Parameters
Name
Setting Range
Increments
Initial Value
Refer to
page