25
In
p
ut
te
rm
inal
f
unc
tio
n ass
ignm
e
nt
178
STF terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 60, 62, 64 to 67,
9999
1
60
179
STR terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 61, 62, 64 to 67,
9999
1
61
180
RL terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 62, 64 to 67, 9999
1
0
181
RM terminal function selection
1
1
182
RH terminal function selection
1
2
183
RT terminal function selection
1
3
184
AU terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 62 to 67, 9999
1
4
185
JOG terminal function selection
0 to 8, 10 to 12, 14, 16,
24, 25, 62, 64 to 67, 9999
1
5
186
CS terminal function selection
1
6
187
MRS terminal function selection
1
24
188
STOP terminal function selection
1
25
189
RES terminal function selection
1
62
Ou
tp
ut
te
rmin
al
fu
n
ct
io
n as
si
gn
m
ent
190
RUN terminal function selection
0 to 5, 7, 8, 10 to 19, 25,
26, 45 to 47, 64, 70, 90 to
96, 98, 99, 100 to 105,
107, 108, 110 to 116, 125,
126, 145 to 147, 164, 170,
190 to 196, 198, 199, 9999
1
0
191
SU terminal function selection
1
1
192
IPF terminal function selection
1
2
193
OL terminal function selection
1
3
194
FU terminal function selection
1
4
195
ABC1 terminal function selection
0 to 5, 7, 8, 10 to 19, 25,
26, 45 to 47, 64, 70, 90,
91, 94 to 96, 98, 99, 100 to
105, 107, 108, 110 to 116,
125, 126, 145 to 147, 164,
170, 190, 191, 194 to 196,
198, 199, 9999
1
99
196
ABC2 terminal function selection
1
9999
Mu
lti-s
pe
ed
se
tti
n
g
232 to 239
Multi-speed setting 8 speed to 15 speed
0 to 400Hz, 9999
0.01Hz
9999
240
Soft-PWM operation selection
0, 1
1
1
241
Analog input display unit switchover
0, 1
1
0
242
Terminal 1 added compensation amount
(terminal 2)
0 to 100%
0.1%
100%
243
Terminal 1 added compensation amount
(terminal 4)
0 to 100%
0.1%
75%
244
Cooling fan operation selection
0, 1
1
1
Slip
co
m
pen
sat
ion
245
Rated slip
0 to 50%, 9999
0.01%
9999
246
Slip compensation time constant
0.01 to 10s
0.01s
0.5s
247
Constant-output region slip
compensation selection
0, 9999
1
9999
250
Stop selection
0 to 100s, 1000 to 1100s,
8888, 9999
0.1s
9999
251
Output phase failure protection
selection
0, 1
1
1
Fr
eq
uen
cy
co
m
pen
sa
tion
fu
n
ctio
n
252
Override bias
0 to 200%
0.1%
50%
253
Override gain
0 to 200%
0.1%
150%
Li
fe
c
he
ck
255
Life alarm status display
(0 to 15)
1
0
256
Inrush current limit circuit life display
(0 to 100%)
1%
100%
257
Control circuit capacitor life display
(0 to 100%)
1%
100%
258
Main circuit capacitor life display
(0 to 100%)
1%
100%
259
Main circuit capacitor life measuring
0, 1
1
0
260
PWM frequency automatic switchover
0, 1
1
1
Function
Parameters
Name
Setting Range
Increments
Initial Value
Refer to