Name

Type

Applications, Specifications, etc.

Applicable

Inverter

Plug

-in T

y

p

e

16-bit digital input

FR-A7AX

⋅ This input interface sets the high frequency accuracy of the

inverter using an external BCD or binary digital signal.
BCD code 3 digits (maximum 999)
BCD code 4 digits (maximum 9999)
Binary 12 bits (maximum FFFH)
Binary 16 bits (maximum FFFFH)

Shared among all
models

Digital output
extension analog output

FR-A7AY

⋅ This option provides the inverter with open collector outputs

selected from among the standard output signals.

⋅ This option adds two different signals that can be

monitored at the terminals FM and AM, such as the output
frequency, output voltage and output current.

⋅ 20mADC or 5VDC (10V) meter can be connected.

Relay output

FR-A7AR

⋅ Output any three output signals available with the inverter

as standard from the relay contact terminals

Co

mmu

ni

ca

tio

n

CC-LINK

FR-A7NC

⋅ This option allows the inverter to be operated or monitored

or the parameter setting to be changed from a computer or
PLC.

* For the FR-A7NC (CC-Link), the above operations can be done from the PLC

only.

L

ON

W

ORKS

FR-A7NL

Parameter unit (Eightlanguages)

FR-PU04

Interactive parameter unit with LCD display

Shared among all
models

Parameter unit connection cable

FR-CB20

Cable for connection of operation panel or parameter unit

indicates a cable length. (1m, 3m, 5m)

Operation panel connection

connector

FR-ADP

Connector to connect the operation panel (FR-DU07) and

connection cable

      

S

tand

-alon

e Sh

ar

ed

Intercompatibility attachment

FR-AAT

Attachment for replacing with the F700 series using the

installation holes of the FR-F500.

According to
capacities

FR-A5AT

Attachment for replacing with the F700 series using the

installation holes of the FR-A100 and FR-

A200

AC reactor

FR-HAL

For harmonic current reduction and inverter input power factor

improvement (total power factor approx. 88%)

For 200V class
55K or less, 400V
class 75K or less

DC reactor

FR-HEL

For harmonic current reduction and inverter input power factor

improvement (total power factor approx. 93%)

For the 55K or
less

Line noise filter

FR- BSF01

FR- BLF

For line noise reduction

Shared among all
models

BU type brake unit

BU

For increasing the braking capability of the inverter (for high-

inertia load or negative load)

For the 55K or
less

Brake unit

FR-BU

MT-BU5

For increasing the braking capability of the inverter (for high-

inertia load or negative load)

Brake unit and resistor unit are used in combination

According to
capacities

Resistor unit

FR-BR

MT-BR5

Power regeneration common

converter

FR-CV

Unit which can return motor-generated braking energy back

to the power supply in common converter system

For the 55K or
less

Dedicated stand-alone reactor

for the FR-CV

FR-CVL

Power regeneration converter

MT-RC

Energy saving type high performance brake unit which can

regenerate the braking energy generated by the motor to the

power supply.

For the 75K or
more

High power factor converter

FR-HC

MT-HC

The high power factor converter switches the converter

section on/off to reshape an input current waveform into a

sine wave, greatly suppressing harmonics. (Used in

combination with the standard accessory.)

According to
capacities

Surge voltage suppression filter

FR-ASF

Filter for suppressing surge voltage on motor

For 400V class
55K or less

Sin

e wa

ve

fil

te

r

Reactor

MT-BSL

Reduce the motor noise during inverter driving

Use in combination with a reactor and a capacitor

For the 75K or
more

Capacitor

MT-BSC

Option and Peripheral Devices