MITSUBISHI ELECTRIC INVERTER FR-F700 User Manual
Page 23
Features
Standard
Specifications
Outline
Dimension
Drawings
Operation
Panel
Protective
Functions
Options
Instructions
Motor
Compatibility
W
arranty
Inquiry
Peripheral Devices
Why energy
savings?
Te
rminal Connection
Diagram
Te
rminal Specification
Explanation
Parameter
List
Explanations
of
Parameters
24
C
omme
rc
ia
l p
o
we
r
su
pp
ly
-inv
er
te
r
sw
itch
-o
ve
r
135
Commercial power-supply switchover
sequence output terminal selection
0, 1
1
0
136
MC switchover interlock time
0 to 100s
0.1s
1s
137
Waiting time at a start
0 to 100s
0.1s
0.5s
138
Commercial power-supply operation
switchover selection at an alarm
0, 1
1
0
139
Automatic switchover frequency
between inverter and commercial power-
supply operation
0 to 60Hz, 9999
0.01Hz
9999
B
ac
kl
ash
m
eas
ur
es
140
Backlash acceleration stopping
frequency
0 to 400Hz
0.01Hz
1Hz
141
Backlash acceleration stopping time
0 to 360s
0.1s
0.5s
142
Backlash deceleration stopping
frequency
0 to 400Hz
0.01Hz
1Hz
143
Backlash deceleration stopping time
0 to 360s
0.1s
0.5s
144
Speed setting switchover
0, 2, 4, 6, 8, 10, 102, 104,
106, 108, 110
1
4
PU
145
PU display language selection
0 to 7
1
0
C
ur
re
nt
det
ec
tio
n
148
Stall prevention level at 0V input.
0 to 150%
0.1%
120%
149
Stall prevention level at 10V input.
0 to 150%
0.1%
150%
150
Output current detection level
0 to 150%
0.1%
120%
151
Output current detection signal delay
time
0 to 10s
0.1s
0s
152
Zero current detection level
0 to 150%
0.1%
5%
153
Zero current detection time
0 to 1s
0.01s
0.5s
154
Voltage reduction selection during stall
prevention operation
0, 1
1
1
155
RT signal reflection time selection
0, 10
1
0
156
Stall prevention operation selection
0 to 31, 100, 101
1
0
157
OL signal output timer
0 to 25s, 9999
0.1s
0s
158
AM terminal function selection
1 to 3, 5, 6, 8 to 14, 17, 21,
24, 50, 52, 53
1
1
159
Automatic switchover ON range
between commercial power-supply and
inverter operation
0 to 10Hz, 9999
0.01Hz
9999
160
User group read selection
0, 1, 9999
1
9999
161
Frequency setting/key lock operation
selection
0, 1, 10, 11
1
0
Au
to
m
ati
c
re
st
ar
t
fu
nc
tio
n
s
162
Automatic restart after instantaneous
power failure selection
0, 1, 10, 11
1
0
163
First cushion time for restart
0 to 20s
0.1s
0s
164
First cushion voltage for restart
0 to 100%
0.1%
0%
165
Stall prevention operation level for
restart
0 to 150%
0.1%
120%
C
ur
rent
de
te
ct
io
n
166
Output current detection signal retention
time
0 to 10s, 9999
0.1s
0.1s
167
Output current detection operation
selection
0, 1
1
0
168
Parameter for manufacturer setting. Do not set.
169
Cu
mu
la
tiv
e
mo
n
ito
r
cl
ea
r
170
Cumulative power meter clear
0, 10, 9999
1
9999
171
Operation hour meter clear
0, 9999
1
9999
Us
er
gr
ou
p
172
User group registered display/batch
clear
9999, (0 to 16)
1
0
173
User group registration
0 to 999, 9999
1
9999
174
User group clear
0 to 999, 9999
1
9999
Function
Parameters
Name
Setting Range
Increments
Initial Value
Refer to
page