beautypg.com

Milli-volt control lighting instructions – Monessen Hearth VWF30 User Manual

Page 43

background image

27D8520

43

ON

OFF

PIILO

T

OPERATING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. Turn gas control knob clockwise

to the “OFF” position, and turn ON/OFF switch to

“OFF” position.

4. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell

gas, STOP!

5. From “OFF” position, turn the gas control knob counterclockwise

to “PILOT” position.

Push in control knob for 5 seconds.

6. With the control knob pushed in, light pilot with match.
7. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from

shutting off the gas while the probe is warming up. Release the control knob.

8. Turn gas control knob counterclockwise

to the “ON” position.

9. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF

switch to “ON” position.

10. If the gas logs will not operate, follow the instructions “To Turn Off Gas to Heater” and call your

service technician or gas supplier.

Figure 148 - Control Knob

Figure 147 - Pilot

TO TURN OFF GAS TO HEATER

1. Turn control knob clockwise

to OFF position to completely shut off the heater.

2. If applicable: Turn ON/OFF switch to OFF position.

MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS

Figure 149 - On/Off Switch

This manual is related to the following products: