beautypg.com

Monessen Hearth VWF30 User Manual

Page 3

background image

27D8520

3

INSTALLER
Please leave these instructions with the appliance.

OWNER
Please retain these instructions for future reference.

IMPORTANT SAFETY INFORMATION

1. The installation, combustion and ventilation air must

conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1, or
the CAN/CGA-B149 Installation code (series). This unit
complies with ANSI Z21.60 decorative gas appliance for
installation in solid-fuel burning fireplace.

2. Installation and repair should be done by a qualified

service person. MHS Vented Gas Logs must be installed
only in a masonry or a UL 127 solid-fuel fireplace with
minimum venting requirements, see installation sec-
tion.

3. To prevent malfunction, gas log set and flue should be

cleaned at least annually by a professional service person.
More frequent cleaning may be required due to exces-
sive lint from carpeting, etc. It is imperative that control
compartments, burners and circulating air passageways
be kept clean.

4. A damper clamp must be installed to provide the mini-

mum permanent vent opening to vent flue products,
Refer to installation instructions.

5. Never burn solid fuels in a fireplace where a gas log set

is installed.

6. This appliance must NOT be used with glass

doors in the closed position.

A fireplace screen

must be in place when the log set is burning. Provisions
for adequate combustion air must be provided. Adequate
combustion air usually results in all flames curling into
the fireplace away from the screen and up the flue.

8. Keep room area clear and free from combustible materi-

als, gasoline and other flammable vapors and liquids.

9. Children and adults should be alerted to the hazard of

high surface temperature and should stay away to avoid
burns or clothing ignition.

10. Young children should be carefully supervised when they

are in the same room with the gas log set in operation.

11. Do not place clothing or other flammable material near

the fireplace when the gas logs are in use.

12. Do not use this gas log set if any part has been underwater.

Immediately call a qualified service technician to inspect
the gas logs and replace any part of the control system
and any gas control which has been under water.

13. The gas log set must be isolated from the gas supply

piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5kPa).

14. Secure gas log set to fireplace.
15. This log set will burn off the paint on the front grate bar.

Note: See cleaning section for refurbishing.

16. FOR MASSACHUSETTS RESIDENTS ONLY:

IMPORTANT

Read these instructions carefully before installing or trying to operate this gas log set.

• Any change to this appliance or its controls can be dangerous.

• Improper installation or use of the heater can cause serious injury or death from fi re,

burns, explosion or carbon monoxide poisoning.

• Do not allow fans to blow directly into the fi replace. Avoid any drafts that alter burner

fl ame patterns.

• Do not use a blower insert, heat exchanger insert or other accessory, not approved for

use with this appliance where applicable.

W

ARNING

This appliance is for installation only in
a solid fuel burning fi replace (masonry
fi replace or manufactured fi replace).

W

A

RNING

This product must be installed by a
licensed plumber of gas fi tter when
installed within the Commonwealth of
Massachusetts.

W

A

RNING

Installation of this vented gas log in the Commonwealth
of Massachusetts requires the damper be permanently
removed or welded in the full open position. In addition, a
naturally vented gas log may not be installed in a bedroom
or bathroom in the Commonwealth of Massachusetts.
Flex line installation must not exceed 36".

This manual is related to the following products: