USER INSTRUCTIONS

EMERGENCy SHUT OFF

If the batteries fail during use of the fire, move the switch to

the OFF (O) position, Diagram 3

(This switch is set to be ON during normal operation and

must remain ON)

3

AR1933

3. CLEANING THE STUDIO

3.1 Make sure the fire and surrounds are cool before cleaning.

Use:

• A damp cloth for the painted frame

• Use soap and water to clean the glass

3.2 Opening the Glass Door

3.2.1 Steel Frame only

[If fitted with a Steel Frame, this needs to be removed

first:

• Lift the frame upwards off its four support brackets,

Diagram 4

4

AR2136

3.3 All models

Using the allen key provided to release the upper and lower

catches on the right side of the door:

• Slide the allen key into the gap between the door and

frame and locate the catch of the upper lock

• Push the allen key DOWN

• Slide the allen key into the gap and locate the lower lock

• Push the allen key UP

5

AR2119

AR2119

• Open the door outwards

When closing the door ensure the door catches are fully

engaged

.

4. CHANGING THE STUDIO BATTERIES

The appliance batteries are located behind the wall switch

plate.

• Undo the two screws securing the wall switch and plate

and remove, Diagram 6

6

AR1887

• Correctly position the four new AA size batteries

• Re-assemble the battery holder as shown in Diagram 7

• Ensure the touch pad cable is tucked to the left on fitting

the wall plate back onto the wall, Diagram 7

PLEASE ENSURE NO WIRES ARE TRAPPED BEFORE

REPLACING THE WALL PLATE. THE TOUCH PAD LEAD

IS EASILy DAMAGED

.