8.2.2 The appliance is factory set for top exit.
8.3 A 152mm (6") diameter hole in the wall or ceiling is

required to install the flue. This can be achieved by either:

a) Core drill

b) Hammer and chisel

• Drill small holes around the circumference when using

method b. Make good both ends of the hole.

8.4 • Allow enough room either above or to the side of the

appliance to assemble the flue on top

• Assemble a horizontal flue in the following order:

- Vertical section

- 90° elbow

- Horizontal plus terminal

• Support the opening of a masonry installation with a

lintel

8.5 Only the horizontal terminal section can be reduced in size.

To find the length:

• Measure from the outside of the wall to the stop on the

90°

Add 10 mm to the outlet end

Measure from the edge of the slots closest to

the wall

Mark around the flue, Diagram 31

31

AR0629

10mm

A wall plate is supplied to fix the flue to the wall:

• Bend the tab to 90°

• Assemble the plate onto the flue but wait to secure to

wall and flue after the flue is fully assembled, Diagram 31

8.6 The cardboard fitment in the terminal is used to support the

flue whilst it is cut to length. ONCE CUT TO SIZE,

REMOVE THE CARDBOARD REMNANT,

Diagram 32.

32

AR0630

9. ASSEMBLING THE APPLIANCE

There are two possible points of entry for your gas pipe

depending on the location of your appliance, one located

on the underside and the other located on the left-hand

side:

• Choose the most suitable for your installation

• Slit with a sharp knife before bringing through the supply

pipe, Diagram 33


9.1 • Remove the compression elbow from the appliance and

connect it to the gas supply pipe

As the appliance is fitted into the enclosure:

• Pass the elbow and supply pipe through the silicone

panel

PURGE THE SUPPLy PIPE. This is essential to expel any

debris that may block the gas controls.

• Connect the elbow to the appliance inlet pipe, Diagram

33

33

AR1888

9.2 To reassemble the control unit:

• Put the left-hand side of the control unit into the left

corner of the interior, before lowering down and sliding to

the right

• Refix with the 13 screws

• Connect the elbow to the appliance inlet pipe, Diagram

33

INSTALLATION INSTRUCTIONS