Installation instructions, Site requirements – Stovax Studio 22 User Manual
Page 15
15
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
5. APPLIANCE LOCATION
5.1 Please note this appliance has been specifically designed for
studwork applications although installation into other
constructions, including masonry, is entirely feasible. There
are two methods of installation, see Installation
Instructions 3.2 Frame, 3.3 Edge
5.2 This appliance must stand on a non-combustible hearth/
platform that is at least 12mm thick.
NOTE: It is recommended you construct the back panel
of the fireplace from natural materials cut into three or
more sections to prevent cracking. Resin-based materials
may not be suitable. This appliance is an effective heat
producer and attention must be paid to the construction
and finish of the fireplace.
5.3 A combustible shelf must be:
• maximum 150mm in depth
• minimum, 400mm high above the fire
A combustible side wall must be a minimum of 150mm
from the appliance.
5
AR2077