beautypg.com

Installation instructions, Installation, Stud work installation – Stovax Studio 22 User Manual

Page 18: Studwork installation for studio with frames

background image

18

INSTALLATION INSTRUCTIONS

INSTALLATION

3. STUD WORk INSTALLATION

THERE ARE THREE TyPES OF INSTALLATION INTO

STUDWORk DESCRIBED IN THE FOLLOWING PAGES:

1)

FOR STUDIO 22 WITH EITHER THE STEEL, PROFIL

OR BAUHAUS FRAME, SEE SECTION 4

2)

FOR AN INSTALLATION WHERE THE STUDIO 22 SITS

FLUSH TO THE FINISHED 'EDGE' OF THE WALL, SEE

SECTION 5

3)

FOR A FURTHER 'EDGE' INSTALLATION PROVIDING

A COOL WALL ABOVE THE APPLIANCE TO ALLOW

CUSTOMERS TO HANG PICTURES ETC., SEE SECTION

6

3.1

DISTANCE TO COMBUSTIBLE MATERIAL

COMBUSTIBLE PARTS OF THE STUDWORk MUST BE

kEPT BEyOND THE MINIMUM DIMENSIONS SHOWN

IN DIAGRAM 8. EVEN IF THE FRAMEWORk IS

PROTECTED By NON-COMBUSTIBLE MATERIAL, yOU

MUST MAINTAIN THESE DIMENSIONS.

8

AR2077

3.2 DO NOT PACk THE VOID AROUND OR ABOVE THE

APPLIANCE WITH INSULATION MATERIALS SUCH AS

MINERAL WOOL.

3.3 THE VOID BUILT FOR THE APPLIANCE MUST BE

VENTILATED TO PREVENT A BUILD-UP OF HEAT. IF THE

VOID IS SEALED, THEN yOU MUST FIT VENTS AT BOTH

LOW AND HIGH LEVELS OF APPROXIMATELy 50CM

2

EACH. THESE VENTS MUST TAkE COLD AIR FROM THE

ROOM AND RETURN WARM AIR BACk INTO THE

ROOM

3.4 AN ACCESS HATCH MUST BE LEFT IN THE SIDE OF THE

CHIMNEy BREAST FOR FUTURE SERVICING AND

INSPECTION OF THE FLUE AND APPLIANCE.

4. STUDWORk INSTALLATION FOR

STUDIO WITH FRAMES

• Build the studwork chimney breast and enclosures to

the desired size to include the protected platform at the

required height.

• Line the aperture for the appliance with 12mm thick non-

combustible material as shown, Diagram 9

9

AR1902

• Ensure the clearances are maintained, see Diagram 8

• Site the appliance and decide on flue requirements

• Cut a hole for the flue exit - see Installation

Instructions, Flue Assembly

• Provide gas services into the appliance void on the left-

hand side

Because no combustible material can be used above the

fire, we provide a support bar:

• Mark out the position to fit the supplied top support bar

into the studwork at the correct height. This bar needs to be

recessed into the studwork, Diagram 10

10

AR1903

Detail A