INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
Note: This appliance must only be installed with the flue
supplied.
You must adhere to the following:
1.1 The flue must be sited in accordance with BS5440: Part 1
(latest edition). See Diagram 1.
1.2 Fit a guard to protect people from any terminal less than 2
metres above any access such as level ground, a balcony or
above a flat roof.
1.3 All vertical and horizontal flues must be securely fixed and
fire precautions followed in accordance with local and
national codes of practice.
1.4 A restrictor may be required. Refer to Technical
Specifications on page 9.
1.5 Three types of flue termination are possible, rear, top exit
horizontal and top exit vertical. To measure for a top exit
horizontal terminal:
• Decide on the terminal position
• Measure the height from the top of the appliance to the
centre of the required outlet.
For minimum and maximum flue dimensions see Section 2,
Flue Options.
• Allow enough room either above or to the side of the
appliance to assemble the flue on top
• Assemble a horizontal flue in the following order:
- Vertical section
- 90° elbow
- Horizontal plus terminal
• Support the opening of a masonry installation with a
lintel.
1.7 Only the horizontal terminal section can be reduced in size.