beautypg.com

Environmental specifications – Gateway 9315 User Manual

Page 133

background image

128

www.gateway.com

Environmental specifications

The following specifications identify maximum environmental conditions. At no time
should the server run under conditions which violate these specifications.

Variable

Requirements

Temperature

Maximum rate of change: 18°F (10°C) per hour

Nonoperating: -40° to 158°F (-40° to 70°C)

Operating: 50° to 95°F (10° to 35°C); derated 0.9°F (0.5°C) for every
1,000 feet (305 meters). Use of 2 GB DIMMs derates the server to
86°F (30°C)

Altitude

10,000 feet (3,048 meters) maximum

Humidity

Nonoperating: 90% relative (noncondensing) at 86° F (30° C)

Shock

Operating - 2.0 g, 11 msec, 1/2 sine

Packaged - operational after an 18” fall

Electrostatic
discharge (ESD)

Tested to 15 kilovolts (kV); no component damage