Check list – Furuno FSV-24 User Manual
Page 68

AP-1
Check List
Ship Name Date / / Location
SCANNING
SONAR
TYPE FSV-24
RESULT
Monitor unit (FSV-2400)
Options
Control unit (FSV-2401)
CS-120A
Processor unit (FSV-2402)
VI-1100A
Transceiver unit (FSV-241E)
CS-170
Power supply unit (FSV-242)
FSV-2451(5m),FSV2452(15m)
Hull unit (FSV-243E/244E )
S/N
Reference
Frequency
24KHz
Transducer location
Note:
NO CHECK
ITEMS
CONTENT
RESULT
DATA
1
Unit installation
All units are installed according to installation
manual.
Good/No Good
2
Grounding
Copper plate should be connected for the
following units.
1.Power supply unit
2.Transceiver unit
3.Junction box(Option)
IV-8sq is connected for the following units.
1.Raise/lower box
2.Processor unit
3.Monitor unit
Good/No Good Sheet 1
3
Connection
Check the connection between each unit.
1.Transducer-Transceiver unit
2.Transceiver unit-Processor unit
3.Processor unit-Monitor unit
4.Monitor unit-Control unit
5.Processor unit- Other equipments
6.Ship’s mains-Power supply unit
7.Ship’s mains-Hull unit
8.Ship’s mains-Processor unit
Good/No Good Sheet 1
4 Power
Supply
(Ship’s mains)
Check ship’s mains voltage for following units.
1.Power supply unit
2.Raise/lower motor line
Check whether led of phase detector is light or
not.
The 3 phase line must be changed if led is light.
3.Processor unit
Good/No Good Sheet 1
5
Output power
Check output power and +B voltage.
Good/No Good Fig1
6
Test
Check the following tests.
Board test/Panel test/RX test/Channel
test1/Channel test2/Noise test
Good/No Good Sheet2
Installation
manual
7
Setting
Check the user program setting.
Sheet3
8
Operation check Check pictures after turning on the power.
Good/No Good