3-14

3.6.2 Selecting the Net Sonde information


The net depth information from the Net Sonde can be entered from the FNZ port
or CIF port. Depending on the input port, select the DIP switch setting as follows.
The default setting is FNZ.

Input port

DIP switch S3 - #1

FNZ(default) OFF
CIF1 or NMEA2/CIF2

ON

S3

DCON Board (10P6900 or 10P6900S)

Note1: When the NMEA2/CIF2 port is used, the DIP switch S2-#8 on the IFES

board should be OFF. See page 3-13.

Note2: Do not change the setting of S3-#4 (default: OFF). The hull unit may be

damaged if the setting is changed.

3.6.3

Selecting echosounder signal

There are two kinds of echosounder signals, AC signal and DC signal.
Depending on the signal, select the jumper setting at J496 and J497 on the
CONE board as follows. The default setting is AC. See page 3-13 for parts
location.

Input port

Jumper

ES1 J497
ES2/NET J496


Note:
SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output

port are provided for FURUNO echosounder. Therefore, when using
SIGOUT terminal, it is not necessary to change jumper setting.