Synchronizing with echo sounder or other sonar

To synchronize the transmission of the FSV-24 with an echo sounder or other
type of sonar, make connections as shown below.

For current driven KP input

Processor

unit

E/S

Sonar

EXT-KP

EXT-KP-IN-H
EXT-KP-IN-C

8
9

KP signal

For voltage driven KP (12 V) input

Processor

unit

E/S

Sonar

EXT-KP

EXT-12VKP-H

0V

10

7

KP signal

Voltage driven KP output

Processor

unit

E/S,

Sonar,

Current

indicator

EXT-KP

INTKP1

GND

1
2

INTKP2

GND

3
4

INTKP3

GND

5
6

KP signal

Menu setting

See EXT KP INPUT on page 3-8.