background image

ioxadm(8)

System Administration

85

EXAMPLES

EXAMPLE 1

Displaying Temperature, Voltage, Current, and Fanspeed Sensor Readings

The External I/O Expansion Unit (box_id) is identified by serial number.

Use iox@nnnn, where nnnn represents the last four digits of the box serial
number.

Some commands affect only a single component of an External I/O
Expansion Unit system. For example, individual boats and power supplies
may be turned on and turned off independently.

An FRU in an External I/O Expansion Unit (fru) is identified as:

iox@nnnn/iob0

– I/O boat in the left tray (rear view)

iox@nnnn/iob1

– I/O boat in the right tray (rear view)

iox@nnnn/iob0/link

– Uplink card in boat 0

iox@nnnn/iob1/link

– Uplink card in boat 1

iox@nnnn/ps0

– Power supply in the left bay (front view)

iox@nnnn/ps1

– Power supply in the right bay (front view)

XSCF>

ioxadm env -te iox@A3B5

Location Sensor Value Res Units

IOX@A3B5/PS0 T_AMBIENT 28.000 1.000 C

IOX@A3B5/PS0 T_CHIP 28.000 1.000 C

IOX@A3B5/PS0 T_HOTSPOT 31.000 1.000 C

IOX@A3B5/PS0 SWITCH On - SWITCH

IOX@A3B5/PS0 V_12V_ANODE 11.703 0.059 V

IOX@A3B5/PS0 V_12V_CATHODE 11.703 0.059 V

IOX@A3B5/PS0 V_ISHARE 0.632 0.040 V

IOX@A3B5/PS0 I_DC 2.316 0.289 A

IOX@A3B5/PS0 S_FAN_ACTUAL 3708.791 40.313 RPM

IOX@A3B5/PS0 S_FAN_SET 4500.000 300.000 RPM

IOX@A3B5/PS1 T_AMBIENT 28.000 1.000 C

IOX@A3B5/PS1 T_CHIP 29.000 1.000 C

IOX@A3B5/PS1 T_HOTSPOT 31.000 1.000 C

IOX@A3B5/PS1 SWITCH On - SWITCH

IOX@A3B5/PS1 V_12V_ANODE 11.762 0.059 V

IOX@A3B5/PS1 V_12V_CATHODE 11.762 0.059 V

IOX@A3B5/PS1 V_ISHARE 0.672 0.040 V