Page 106

ioxadm(8)
84
SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008
Note –
When a power supply is powered off, the LEDs and fan may still run
since they receive power from both supplies.
poweron
target
Restores full power to an I/O boat or reenables output from the power
supply (PS) that has previously been marked ready-to-remove. When a PSU
is newly installed and the power switch is in the on position, or a boat is
connected to a powered link card, they automatically power themselves on.
However, this command can be used to power a PSU or I/O boat back on that
previously had been powered down for removal as long as the power switch
is in the on position.
reset
target
Reinitializes FRU components used to monitor External I/O Expansion Unit
environmentals. If a boat or link card is specified, the bridge controllers in
the link cards are reset and re-initialized. If a box is specified, the fan
controller and demux in the box are reset and re-initialized along with all
bridge controllers associated with the External I/O Expansion Unit.
setled
[on|off|slow|fast] target led_type
Sets LED state:
off
Off.
on
On.
fast
Fast blink.
slow
Slow blink.
Refer to the entry for led_type in this section for detailed information about
LED types.
target
Specifies the target device which can be a downlink card in a host slot, an
External I/O Expansion Unit, or an FRU in an External I/O Expansion Unit.
The downlink card is identified by the hostpath to the card.
hostpath is platform dependent and indicates the path to the slot on the
host system which contains the downlink card. On SPARC Enterprise
M4000/M5000/M8000/M9000 servers, the hostpath has the following
format:
IOU#0-PCI#0 IO Board 0, PCI-E slot0