Item

Description

Noise [dB]

(Included in main

unit specifications)

Acoustic power level [B]

(Included in main

unit specifications)

Allowable vibration

[m/s

2

(gal)]

Operating (including standby state)

4.0 (400) (synthetic

seismic waves)

Non-operating (*6)

10.0

(1000) (synthetic

seismic waves)

Allowable dust concentration [mg/m

3

]

0.15

Power requirements

Input voltage and number of phases

200 to 240

VAC ±10%

100 to 120

VAC ±10%

Frequency and fluctuation range

50/60 Hz +2/-4%

Maximum power

consumption/

apparent power

Operating

Input voltage: 200 V

450 W / 475 VA

Input voltage: 100 V

460 W / 485 VA

Standby

Input voltage: 200 V

10 W / 40 VA

Input voltage: 100 V

10 W / 35 VA

Power factor (*7)

0.95 or more

Rush current [A] (Inrush time) (*8)

25 or less

Leakage current [mA] (*9)

3.5 or less

*1 The dimensions do not include protrusions.

*2 The values are for the device with all options installed.

However, the values do not include the weight of mounted rack-mount rails (7 kg) and cables.

*3 If the intake air temperature is high (but within the normal temperature range), the fan enters high-speed mode

even when operation is normal.

*4 Condensation is not permitted.

*5 The temperature requirements depend on the altitude at the installation site.

- Installation at 0 to 500 m (0 to 1640 ft.) above sea level: 5 to 35°C (41 to 95.0°F)

- Installation at 500 to 1000 m (1640 to 3281 ft.) above sea level: 5 to 34°C (41 to 93.2°F)

- Installation at 1000 to 1500 m (3281 to 4921 ft.) above sea level: 5 to 33°C (41 to 91.4°F)

- Installation at 1500 to 3000 m (4921 to 9843 ft.) above sea level: 5 to 30°C (41 to 86.0°F)

The altitude specifications for the installation site include an allowable margin of error of ±100 m.

*6 "Non-operating" refers to the condition where a device has been disconnected from the power supply and stored.

*7 This is the value during operation.

*8 This value is for a single input cable.

*9 This value is for a single device.