8
Unit 2
Type in :-
--> hdlc set interface local adminstatus down
↵↵
--> hdlc set interface local ntimes64k 0
↵↵
--> nx64 set interface local adminstatus up
↵↵
--> nx64 set interface local type v35
↵↵
--> nx64 set interface local ntimes64 LineRate
↵↵
--> system config save normal
↵↵
8.17.3 V35 & G703 Example configuration
To set up a 1024 kbps V35 link and a G703 1024kbps link starting from the factory default settings. Because
only 16 of the 32 G703 timeslots are to be used only 16 times slots are being set to enable.
Unit 1
Mode
CO
Line Rate
2048kbps
N*64 User Port
V35 DCE @ 1024k
G703 User Port
E1 Framed
Framming
E1
G703 Timeslots
16 timeslots activated
Timing
Local
Unit 2
Mode
CPE
Line Rate
RateAdaption
N*64 User Port
V35 DCE @ 1024k
G703 User Port
E1 Framed
Framming
E1
G703 Timeslots
16 timeslots activated
Timing
Local