6.4
G703
To set up a G703 link. Start from factory default configuration. Set one unit to be a CO as described above.
Then on both units (CO and CPE) input the following commands.
First disable the Ethernet port, which is enabled by default. Type in:
--> hdlc set interface local adminstatus down
↵↵
--> hdlc set interface local ntimes64k 0
↵↵
Then enable the G703 port. Type in:
--> ds1 config set interface local adminstatus up
↵↵
--> ds1 config set interface local chanelization disabled
↵↵
This will enable G703 port in the following configuration
·
E1 Framed mode
·
AM200 as the timing master for the link (both CO and CPE set to local timing)
·
All 32 timeslots active
Note. The current line rate must be 2048k or greater for this configuration to operate correctly
Customer
Terminal
Customer
Terminal
G.703
copper pair
timing
timing
AM200
CO
AM200
CPE