COMPLIANCE NOTES & SAFETY INSTRUCTIONS
Caution: - Hazardous voltages inside the equipment
Safety Instructions:
This apparatus must be installed and maintained by SERVICE PERSONNEL.
There are NO user serviceable parts inside the modems.
Caution: - Electrostatic sensitive devices inside the equipment
Electrostatic discharge (ESD) Warning:
Antistatic precautions should be observed at all times.
Power Rating Information - AC Version:
Voltage Rating
85Vrms to 250Vrms
Maximum Current
100mA
Frequency Range
50 - 60Hz
Power Rating Information - DC Version:
Voltage Rating
-18V to -72V
Maximum Current
222mA
Disconnect Device Statement:
For the AM200 DC Version the DC input socket serves as the disconnect device.
TTE - Network Safety Statement:
The AM200 is a Class 1 product and must be connected to a reliable earth connection. If the MAINS EARTH
cannot be guaranteed to be PROTECTIVE EARTH, then a PROTECTIVE EARTH conductor must be connected
to the M3 stud on the REAR PANEL of the unit.
Safety Classification of traffic Ports
The DSL line connection has a safety status of TNV-3
10/100BaseT - 8 WAY RJ45 connection has a safety status of UNEARTHED SELV.
X21/V35 - 25 WAY FEMALE D-Type connection has a safety status of EARTHED SELV.