ATL User Guide
AM200 Modem
120
13.3 AC POWER INLET
AC power is fed via a standard 3-pin 250V 2.5A IEC/EN 60320-1/C6 socket. A single pole rocker switch next
to the power socket is used to switch the AM200 On/Off. A power cord fitted with a country specific mains
plug is supplied with the unit. This should be plugged into a suitable power supply with earth protection to
provide ESD protection for the unit
13.4 DC POWER INLET
DC power is fed in via the three-pin socket on the rear panel. The cable assembly is shown in Figure 70.
A connection from CGND to earth is required for ESD protection of the unit.
If the unit is line powered, the ground connection must be made to the earth bonding point on the rear panel.
(M3 screw)
Mating connector
Molex Minifit Junior Receptacle
Molex Part Number: 39-01-4031
Molex female contact
Molex Part Number: 39-00-0039
1
2
-48V
0V
3
CGND
WHITE
RED
BLACK
2
1
3
I
0