Specifications, Environmental specifications, Mechanical specifications – HP PROLIANT ML330 G6 User Manual
Page 112
![background image](/manuals/90735/112/background.png)
Specifications 112
Specifications
Environmental specifications
Specification Value
Temperature
Operating
1
10°C to 35°C (50°F to 90°F)
Non-operating 30°C to 60°C (-22°F to 140°F)
Maximum rate of temperature
change
Operating
2,3
10°C/hr
(18°F/hr)
Non-operating 20°C/hr
(36°F/hr)
Relative humidity
(noncondensing)***
Operating
10% to 90%
Non-operating
5% to 95%
Maximum wet bulb temperature
(non-condensing)
Operating 28°C (82.4°F)
Non-operating 38.7°C
(101.7°F)
Altitude
Operating
2
3,050 m (10,000 ft)
Non-operating
9144 m (30,000 ft)
Maximum rate of altitude
change
Operating
3,000 m (10,000 ft)
Non-operating
9,144 m (30,000 ft)
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight is allowed.
2
The type and number of options installed can limit the upper limit.
3
System performance may be reduced if operating with a fan fault above 30ºC (86ºF).
Mechanical specifications
Specification Value
Height
20.0 cm (7.87 in)
Depth (without bezel)
42.70 cm (16.81 in)
Width
61.30 cm (24.13 in)