Troubleshooting – HP A3312A User Manual
Page 85
& Diagnostics
Infor
79
Troubleshooting
Byte
-13
Description
31 00
Medium format corrupted
31 01
Format failed
32 00
No defect spare location available
37 00
Parameter rounded
3D 00
Invalid bits in identify message
3E 00
LUN has not yet self-configured
3F 00
Target operating conditions have changed
3F 01
Microcode changed
3F 02
Changed operating definition
40 01
DRAM parity error
42 00
Power-on or self-test failure
43 00
Message error
44 00
Internal target failure
45 00
Select/reselection failure
47 00
SCSI parity error
48 00
Initiator detected error message received
49 00
Invalid message error
4C 00
LUN failed self-configuration
4E 00
Overlapped commands attempted
5B 00
Log exception
5B 01
Threshold condition met
5B 02
Log counter at maximum
5B 03
Log list codes exhausted
5C 00
RPL status change
5C 01
Spindles synchronized
5C 02
Spindles not synchronized
65 00
Voltage fault
80 00
General firmware error qualifier