Appendix B. Product Specifications
132
Specifications
Electromagnetic:
Radiated:
5 V/m, 14 kHz to 1000 Mhz
Conducted:
3 Vrms, 30 kHz to 50 kHz; 1 Vrms, 50 kHz to 400 MHz
Magnetic:
47.5 Hz to 198 Hz @ 4 Gauss external field
Electrostatic Discharge:
1-10 kV operating; 1-25 kV nonoperating
Magnetic Interference, Nonop:
< 5.25 mGauss @ 4.6 m; < 2 mGauss @ 0.7 ft
Magnetic Interference, Operating:
< 5 mGauss p-p @ product surface
Magnetic Susceptibility:
47.5 Hz to 198 Hz @ 4 Gauss external field
Radiated Susceptibility:
3 V/m external field, 14 kHz to 1000 MHz
Conducted Susceptibility:
3 Vrms, 30 kHz to 50 kHz; 1 Vrms, 50 kHz to 400 MHz
ESD, Operating:
0 to 15 kV, air discharge
ESD, Nonop:
15 kV to 25 kV, air discharge
Heat Dissipation:
Min. Config.
1
:
66 W (225 Btu/hr; 57 kcals/hr)
Max. Config.
2
:
177 W (603 Btu/hr; 152 kcals/hr)
Airflow Space:
102 mm (4.02 in) min. front and rear
Temperature:
Operating (Disk/DDS Tape):
5° to 40° C (41° to 104° F)
Operating Gradient (Disk):
20
°
C/hr (68
°
F/hr) max
Operating Gradient (DDS Tape):
10
°
C/hr (50
°
F/hr) max
Nonop (Disk/DDS Tape):
-40° to 65° C (-40° to 149° F)
Nonop (DDS Tape Media):
-40° to 45° C (-40° to 113° F)
Nonop Gradient (Disk/DDS Tape):
20
°
C/hr (68
°
F/hr) max
Humidity:
Maximum Wetbulb Temperature:
26° C (79° F)
Operating Gradient:
10% RH/hr
Operating (Disk Module):
8 to 80% RH (noncondensing)
Operating (DDS Tape Module
w/Media):
20 to 80% RH (noncondensing)
Nonop (Disk Module):
5 to 90% RH (noncondensing)
Nonop (DDS Tape Module w/Media):
20 to 80% RH (noncondensing)
Altitude:
Operating:
0 to 3,048 m (0 to 10,000 ft.)
Nonop:
3,048 to 4,572 m (10,000 to 15,000 ft.)
Shock:
Operating
3
:
0.635 cm (0.25 in) tilt drop
Notes:
1. Minimum Configuration is 2 fan modules, 1 power module, no disk modules
2. Maximum Configuration is 2 fan modules, 2 power modules, eight 1-inch disk modules
3. No damage; no data loss