Troubleshooting – HP A3312A User Manual
Page 83

Troubleshooting & Diagnostics
Diagnostic Information
77
Troubleshooting
Table 18. Disk Module Additional Sense Code/Qualifier Codes
Byte
12-13
Description
00 00h
No Additional Sense information
01 00h
No index/sector signal
02 00h
No seek complete
03 00h
Peripheral device write fault
04 00h
LUN not ready; cause not reportable
04 01h
LUN not ready; becoming ready
04 02h
LUN not ready; initializing command required
04 03h
LUN not ready; manual intervention required
04 04h
LUN not ready; format in progress
08 00h
LUN communication failure
08 01h
LUN communication time-out
08 02h
LUN communication parity error
09 00h
Track following error
09 04h
Head select fault
0A 00h
Error log overflow
0C 00h
Write error
0C 01h
Write error recovered with auto-reallocation
0C 02h
Write error; auto-reallocation failed
10 00h
ID CRC or ECC error
11 00h
Unrecovered read error
11 01h
Read retries exhausted
11 02h
Error too long to correct
11 04h
Unrecovered read error; auto reallocation failed
12 00h
Address mark not found for ID field
12 01h
Recovered data without ECC using previous sector ID
12 02h
Recovered data with ECC using previous sector ID
14 00h
Sector not found
14 01h
Record not found
15 00h
Random positioning error
15 01h
Mechanical positioning error
15 02h
Positioning error detected by read of medium
16 00h
Data synchronization mark error
17 00h
Recovered data with no error correction applied
17 01h
Recovered data using retries